algorithmic modeling for Rhino
Hi Aryan,
I would say a first rough estimate would be to take a reasonable value between H/300 and H/500 (for a static load), so around 30cm deflection.
That being said, there are many criteria on displacement for high rise building depending on what you consider. In high rise buildings, dynamic loads like wind are usually governing the design, especially if you consider comfort. In this case, a more appropriate design criterion would be a "maximal acceleration". I don't have the figures in mind, but I think that we perceive vibrations at 2 milli-g.
You can also check the inter-storey drift, which should not exceed h/100, where h is the inter-storey height.
Best,
Romain
Hi Romain,
Thanks for your reply. How can I measure inter-storey drift using Karamba? Is there any specific component for checking that?
Hi Aryan,
I don't think that Karamba does this automatically, you need to do a little post-treatment here. You'll have to retrieve nodes belonging to each floor and compute their relative displacement (compute the difference and compare with the inter-storey height). If you have vertical elements on the facade, this task should be quite easy (just take the end nodes of these elements).
Many thanks Romain! That's a good trick.
Welcome to
Grasshopper
Added by Parametric House 0 Comments 0 Likes
Added by Parametric House 0 Comments 0 Likes
Added by Parametric House 0 Comments 0 Likes
Added by Parametric House 0 Comments 0 Likes
© 2024 Created by Scott Davidson. Powered by